Apg MPX Slave Sensor user manual Uživatelský manuál Strana 24

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 23
MPX Series Magnetostrictive Level Sensors Rev. B, 4/13
24
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
Applicaon Type 7: Pounds
Allows the user to apply a conversion mulplier to the calculated level reading.
NOTE: the decimal point for the mulplier (40436-40437) is always assumed
to be in the thousands posion, therefore a seng of 206250 = 206.250
actual mulplier.
Example: suppose the product in a tank weighs 206.25 pounds for every inch
of level. With the Units set to inches (Units = 2), enter a mulplier of 206250
into Holding registers 40436-40437.
Register Funcon Value Range
40401 Units 1 to 3
40402 Applicaon Type 7
40404 Decimal Place 0 to 3
40406 Full Distance Typically = Blanking Distance
40407 Empty Distance 0 to 10364 mm
40436-40437 Mulplier 0 to 1000000 (1000 = 1.000)